Consultancies and assessors without in-house simulation
You keep the client and the certification lead. I deliver the model and the credit evidence under your brand, from early design to submission.
Performance simulation for BREEAM and LEED
I build and check the energy and comfort models behind BREEAM and LEED credits, for consultancies, assessors and engineering teams across Europe.
Track record
Every BREEAM model I have delivered was accepted by the assessor.
Who I work with
You keep the client and the certification lead. I deliver the model and the credit evidence under your brand, from early design to submission.
A phase or a project that your team cannot absorb. I join remotely for the modelling scope we agree.
A model built by someone else, a review comment that is hard to answer, or a result that looks wrong before submission.
Services
BREEAM Ene 01 and LEED EA Minimum and Optimize Energy Performance, on an ASHRAE 90.1 Appendix G baseline. Baseline and proposed models, results and the credit report your assessor needs.
Quote energy creditsBREEAM Hea 04 (V6) or Hea 05 (V7) and LEED thermal comfort, with current and future weather on a dynamic model.
Quote comfortI review an OpenStudio or EnergyPlus model built by another team against the scheme manual and ASHRAE 90.1: inputs, assumptions, results. You get a list of findings and draft answers to comments.
Ask for a reviewA senior modeller by the day, for peaks in your own projects.
Book daysPassive design, fabric, or low and zero carbon studies.
Describe the projectWhat you receive
If the assessor, BRE or GBCI raises a comment caused by an error in my model, I correct the model and the documentation at no cost.
Scope
Selected work
Warehouse and offices, Hungary. 64 thermal zones, tested against current and future weather.
Appendix G baseline and proposed models, delivered under the partner's brand. In GBCI review.
| Project | Scheme | Credits | Size | 3D model |
|---|---|---|---|---|
| East Gate Business Park Pro A2, Hungary | BREEAM V6 | Hea 04 | 9,650 m² | Open |
| Tribe Hotel, Budapest Airport | BREEAM V6 | Hea 04 | 15,390 m² | Open |
| Neumann János University campus, Hungary | BREEAM V6 | Hea 04 | 3 buildings | Admin · K1 · K2 |
| BOOM DC2, Belgium | BREEAM V6 | Ene 01 + Hea 04 | 49,546 m² | Open |
| Logistics and offices, Portugal | BREEAM V6 | Ene 01 + Hea 04 | 32,230 m² | Open |
Questions
It depends on the building, the scheme and the credits. I quote a fixed fee per building and per credit within 24 hours of receiving the project details.
For a single credit on one building, usually 10 to 15 days from complete data. Preliminary results come before the final run.
OpenStudio and EnergyPlus, accepted for BREEAM International Ene 01 and for LEED. I don't deliver IES VE or DesignBuilder models.
Nine facts, no full drawing set: scheme and version, target rating, building type, assessment type (fully fitted, shell and core or shell only), number of floors or units, whether the footprint and facade are regular, certification route, current design stage, and the credits you have in mind.
Yes, and it is when a model can still change the building: massing, glazing, shading and systems cost little to change before they are fixed. Most projects reach me after design freeze; I work at either stage.
Yes. Reports can go out under your brand.
Request a quote
I reply within one working day. Your project details are used only to prepare the quote. Prefer email? roberto@r2f.solutions
About
I'm Roberto Ruiz, a mechanical engineer with more than ten years in building energy: research at the University of Liège (2010-2016), building energy efficiency at Sweco Belgium (2018-2021), and R2F, my independent practice, since 2021.
I build my own tools to set up and check models, which is why preliminary results come early and every assumption ends up in the report.
I work remotely, project by project, across Europe, in English, French and Spanish.